DETERMINATION OF THE SEISMIC STRENGTH OF AN OIL PRODUCT STORAGE TANK IN THE PRODUCT-FILLED CONDITION

Authors

  • Phd,. Dots, Sh.M.Davlyatov sh.davlyatov@ferpi.uz Author
  • A.A.Abdurakhmonov Fergana State Technical University Author
  • A.S.Fayziddinov Fergana State Technical University Author

Keywords:

LIRA-SOFT 10.12 software, seismic loads, equivalent stress, stiffening ribs, loads, stiffness parameters, dynamic effects.

Abstract

This article develops technical solutions aimed at reducing the seismic hazard identified in existing storage tanks. Scientific and technical proposals focused on increasing the seismic resistance of the tank are formulated, and constructive strengthening measures are developed based on the results of calculations performed using the LIRA-SOFT 10.12 software package. Based on the obtained results, effective technical solutions are proposed to mitigate seismic effects and enhance the overall safety of the tank.

Downloads

Published

2025-12-18

Issue

Section

Articles

How to Cite

DETERMINATION OF THE SEISMIC STRENGTH OF AN OIL PRODUCT STORAGE TANK IN THE PRODUCT-FILLED CONDITION. (2025). Eureka Journal of Civil, Architecture and Urban Studies, 1(2), 1-9. https://eurekaoa.com/index.php/8/article/view/69