ANALYSIS OF LIMITATIONS, UNCERTAINTIES AND DRAWBACKS OF RESIDUAL WATER RETURN SYSTEMS FROM FIRE HOSE LINES

Authors
  • Nurmuhammad Maxkamov

    Academy of Emergency Situations of the Republic of Uzbekistan

    Author

  • Azizbek Sadirov

    Academy of Emergency Situations of the Republic of Uzbekistan

    Author

Keywords:
Fire hose; residual water; vacuum system; hydraulic losses; two-phase flow; uncertainty; fire apparatus.
Abstract

This paper presents a comprehensive analysis of the limitations, uncertainties, and drawbacks associated with residual water return systems from fire hose lines based on vacuum methods. The key factors affecting the efficiency of water recovery are examined, including hydraulic losses, two-phase flow behavior, hose deformation, and operational conditions. Measurement uncertainties and their impact on experimental results are also evaluated. It is shown that the effectiveness of water return strongly depends on the hose length, configuration, and technical condition of the equipment. The obtained results highlight the need for improved modeling approaches and more reliable system designs.

References

1.Idelchik, I.E.Handbook of Hydraulic Resistance. Moscow: Mashinostroenie, 1992. 672 p.

2.Chugaev, R.R. Hydraulics. Moscow: Energiya, 1982. 672 p.

3.Molchadsky, I.S., Terebnev, V.V. Fire Engineering Equipment. Moscow: Academy of State Fire Service, 2012. 432 p.

4.Terebnev, V.V. Fire Vehicles. Moscow: Academy of State Fire Service, 2006. 365 p.

5.Terebnev, V.V., Podgrushny, A.V. Fire Technical Equipment. Moscow: Academy of State Fire Service, 2015. 390 p.

6.National Fire Protection Association NFPA 1901: Standard for Automotive Fire Apparatus. Quincy, MA: NFPA, 2022.

7.National Fire Protection Association NFPA 1961: Standard on Fire Hose. Quincy, MA: NFPA, 2020.

8.Grimwood P., Sanderson I. A performance-based approach to defining and calculating adequate firefighting water. Fire Safety Journal, 2015, Vol. 78, pp. 155–167.

9.Kaufman M.M., Rosencrants T. GIS method for characterizing fire flow capacity. Fire Safety Journal, 2015, Vol. 72, pp. 25–32.

10.Svensson S. A study of tactical patterns during fire fighting operations. Fire Safety Journal, 2002, Vol. 37, pp. 673–695.

11.Fox, R.W., McDonald, A.T., Pritchard, P.J. Introduction to Fluid Mechanics. 8th ed. Wiley, 2011.

12.White, F.M. Fluid Mechanics. 7th ed. McGraw-Hill, 2011.